YANG Yong1, 2, CHEN Rensheng1, et al. Comparison Experimental Study on Double-ring Infiltrometers with Different Sizes in the Qilian Mountain[J]. 2017, 31(1): 328-331.
YANG Yong1, 2, CHEN Rensheng1, et al. Comparison Experimental Study on Double-ring Infiltrometers with Different Sizes in the Qilian Mountain[J]. 2017, 31(1): 328-331. DOI: 10.13870/j.cnki.stbcxb.2017.01.054.
The double-ring infiltrometer was the most used and classic field method to measure soil water infiltration process and saturated hydraulic conductivity
and the sizes of inner and outer rings of the infiltrometer would affect the determination result. Seven groups of double-ring infiltrometers
with different inner and outer diameters
were laid out and conducted in the grassland flat field in the Heihe river upstream in Qilian mountains
to investigate effects of the size of the infiltrometers on the measurement of the infiltration process and saturated hydraulic conductivity. The results showed that if the inner diameters of double-ring infiltrometer were same
the larger the outer diameter
the smaller the stable infiltration rate and saturated hydraulic conductivity; and if the outer diameters were same
the smaller the inner diameter
the smaller the stable infiltration rate and saturated hydraulic conductivity. The stable infiltration rate and saturated hydraulic conductivity were significantly negative correlation with the buffer index of double-ring infiltrometers
but there was no clear correlation between the initial infiltration rate and the buffer index. Considering the simplicity of installation
water demand and apparatus accuracy
the double-ring infiltrometer with the diameters of 20 cm and 40 cm for the inner and outer rings was recommended to measure the soil water infiltration process and saturated hydraulic conductivity in the mountainous regions.