LIU Zhipeng1, JIANG Guangyi2, SHI Dongmei1, et al. Response of Infiltration Property and Water-holding Capacity of Engineering Accumulation to Rainfall[J]. 2016, 30(5): 240-245.
DOI:
LIU Zhipeng1, JIANG Guangyi2, SHI Dongmei1, et al. Response of Infiltration Property and Water-holding Capacity of Engineering Accumulation to Rainfall[J]. 2016, 30(5): 240-245. DOI: 10.13870/j.cnki.stbcxb.2016.05.040.
Response of Infiltration Property and Water-holding Capacity of Engineering Accumulation to Rainfall
In order to explore the influence of rainfall on infiltration characteristics and water holding capacity of engineering accumulation,laboratory basic soil physical properties analysis and field double ring infiltration methods were used to study the changes of infiltration characteristics and water holding capacity of engineering accumulation in different rainfall conditions and its influencing factors. The results showed that soil bulk density and soil porosity of engineering accumulation had significant differences in different rainfall conditions and slope positions. In different rainfall conditions
the soil bulk density of engineering accumulation of lower of slope from high to low were: Drought (Ⅰ)>light rain (Ⅱ)>moderate rain (Ⅲ)>heavy rain (Ⅳ). Total porosity
capillary porosity
non-capillary porosity in different slope positions from high to low were: Lower>middle>top. In different rainfall conditions
the initial infiltration rate from high to low were: Drought (Ⅰ)>light rain (Ⅱ)>heavy rain (Ⅳ)>moderate rain (Ⅲ)
its size in order to 8.91
5.52
3.96
3.25 mm/min. The stable infiltration rate from high to low were: Drought (Ⅰ)>moderate rain (Ⅲ)>light rain (Ⅱ)>heavy rain (Ⅳ)
its size in order to 4.40,1.45,1.32,0.53 mm/min. In different rainfall conditions
the maximal effective capacity of engineering accumulation of lower of slope from high to low were: Heavy rain (Ⅳ)>light rain (Ⅱ)>drought (Ⅰ)>moderate rain (Ⅲ)
its size in order to 469.03,402.48,378.11,321.88 t/hm2. In different slope positions of engineering accumulation
the field capacity of moderate rain condition was largest. The water-holding capacity of engineering accumulation had a significant positive correlation with total porosity
capillary porosity
non-capillary porosity and infiltration characteristics
while it had a significant negative correlation with soil bulk density. The results could provide important scientific evidence basis for the prevention and control of soil and water loss of engineering accumulation.